TECHNICAL NOTE
File: MP2000_IndividualFunctionDocument_RevC 12/168
Doc Number:
EF.MCD.05.101 11/17/2005
Bit E
Working
cmndError
One shot coil for when another block takes control
from this block.
Bit F
Working
direrr
On if a direction is commanded that is not enabled
by the SVON block.
AW00002
Working
mstr_slave MstrSlave [value of (XW00001) – 1]
AW00003
Working
filter1 Temporary values used to filter bits.
AW00004 OUT camstate Directly controls YW00001 (STATE Output).
AW00005
Bit 0
Working
axisInErr
Goes high for one scan if Axis input is out of range.
AL00006
Working
yFirst First position of slave in Cam table.
AL00008
Working
yLast Last position of slave in Cam table.
AL00010
Working
xLast Last position of Master in Cam table.
AL00012
Working
lastAddress Final register address of Cam table.
AL00014
Working
Window
Tolerance value for engage and disengage
position. Divide XLAST by 120. IE – this window
is 0.8% of the machine cycle.
AL00016
Working
masterpos Value of Master after CAM shift.
AL00018
Working
engage_differe
nce
Distance from engage or disengage point.
AL00020
Working
base_slave_po
s
Reserved
AL00022
Working
fgnOut Value returned from Cam table function generator
AL00024
Working
slave_Pos_Cm
nd
Reserved
AL00026
Working
deltaY
Difference between first and last slave position in
table, used if it’s a one-way cam to offset the slave
AL00028
Working
o pos_o Reserved
AW00030
Working
rdaMult Value for address offset to locate proper RDA
AW00031
Working
Revision Revision Level of Block.
Seitenansicht 11