Sigma II Indexer User’s Manual Monitor Modes
Appendix B-3
(1) Value for the rated torque as 100%. Displays effective torque in 10 second cycles.
(2) Value for the processable regenerative power as 100%. Displays effective power in 10 second cycles.
(3) Value for the processable power when dynamic brake is applied as 100%. Displays effective power in
10 second cycles.
Un80A Program PGMSTEP Pass Through Monitor — — PGMSTEP
Un80B Program EVENT Lapse Time Monitor msec — EVTIME
Un80C Program LOOP Pass Through Monitor — — LOOP
Un80D Serial Command Receipt Letter Trace — — None
Un80E
Serial Command Receipt Letter (Number of Let-
ters)
——None
Un80F
Serial Command Transmission Error Letter (Num-
ber of Letters)
——None
Un810 Serial Command Transmission Letter Trace — — None
Un811
Serial Command Transmission Letter (Number of
Letters)
——None
Table B.1: Monitor Modes