10 Adjustments
10-30
• Related Parameters
The following signals can be monitored.
* When using speed control or force control, the position error monitor signal is not specified.
The analog monitor output voltage is ±8 V (maximum). The output will be limited to ±8 V even if this value is exceeded
in the above calculations.
Parameter Function
Monitor 1 Monitor 2 Monitor Signal Observation Gain Remarks
Pn003 n.0 n.0 Motor speed
1 V / 1000 mm/s
Factory setting for Monitor 2
n.1 n.1 Speed reference
1 V / 1000 mm/s
−
n.2 n.2 Internal force reference 1 V / 100% rated force Factory setting for Monitor 1
n.3 n.3
Position error
∗
0.05 V / 1 reference unit −
n.4 n.4
Position error
∗
0.05 V / 100 reference units −
n.5 n.5 Position reference speed
(converted to motor speed)
1 V / 1000 mm/s
−
n.6 n.6 Motor speed
1 V / 250 mm/s
−
n.7 n.7 Motor speed
1 V / 125 mm/s
−
n.8 n.8
Reserved. Do not set. −
−
n.9 n.9 −
n.A n.A −
n.B n.B −
n.C n.C −
n.D n.D −
n.E n.E −
n.F n.F −