Yaskawa SGDH Linear Sigma Series Bedienungsanleitung Seite 190

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 425
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 189
7 Wiring
7.4.4 I/O Signal Connector (CN1) Terminal Layout
7-26
7.4.4 I/O Signal Connector (CN1) Terminal Layout
The following diagram shows the terminal layout and the signals that are preset before shipping.
Note: 1. Do not use unused terminals for relays.
2. Connect the shield of the I/O signal cable to the connector shell.
Connect to the FG (frame ground) at the SERVOPACK-end connector.
3. The functions allocated to the following input and output signals can be changed by using the
parameters. Refer to 8.3.2 Input Circuit Signal Allocation and 8.3.3 Output Circuit Signal Allo-
cation.
• Input signals: /S-ON, /P-CON, P-OT, N-OT, /ALM-RST, /P-CL, and /N-CL
• Output signals: /TGON, /S-RDY, and /V-CMP (/COIN)
• The above output signals can be changed to /CLT, /VLT, /BK, /WARN, and /NEAR.
Pin
Num-
ber
Signal
Name
Function
1
SG GND
26
/V-CMP-
(/COIN-)
Speed coinci-
dence detec-
tion output
2
SG GND
27
/TGON+ Moving sig-
nal output
3
PL1 Open-collec-
tor reference
power supply
28
/TGON- Moving
signal output
4
−−
29
/S-RDY+ Servo ready
output
5
V-REF Speed refer-
ence input
30
/S-RDY- Servo ready
output
6
SG GND
31
ALM+ Servo alarm
output
7
PULS Reference
pulse input
32
ALM- Servo alarm
output
8
/PULS Reference
pulse input
33
PAO PG dividing
pulse output
Phase A
9
T-REF Force refer-
ence input
34
/PAO PG dividing
pulse output
Phase A
10
SG GND
35
PBO PG dividing
pulse output
Phase B
11
SIGN Reference
sign input
36
/PBO PG dividing
pulse output
Phase B
12
/SIGN Reference
sign input
37
ALO1 Alarm code
output
13
PL2 Open-collec-
tor reference
power supply
38
ALO2 Alarm code
output
14
/CLR Clear input
39
ALO3 Alarm code
output
15
CLR Clear input
40
/S-ON Servo ON
input
16
−−
41
/P-CON P control
input
17
−−
42
P-OT Forward run
prohibit input
18
PL3 Open-collec-
tor reference
power supply
43
N-OT Reverse run
prohibit input
19
PCO PG dividing
pulse output
Phase C
44
/ALM-
RST
Alarm reset
input
20
/PCO PG dividing
pulse output
Phase C
45
/P-CL Forward
external force
limit input
21
−−
46
/N-CL Reverse
external force
limit input
22
−−
47
+24V
IN
External input
power supply
23
−−
48
−−
24
−−
49
−−
25
/V-CMP+
(/COIN+)
Speed coinci-
dence detec-
tion output
50
−−
Seitenansicht 189