6.8 Peripheral Devices
6-21
6
6.8.5 External Regenerative Resistor
Regenerative resistors for SERVOPACKs are internally or externally mounted as shown in the table below.
Regenerative resistors can be externally mounted on all SERVOPACKs. Connect an external regenerative resis-
tor to the SERVOPACK if regenerative energy exceeds the capacity of the SERVOPACK.
If a regenerative resistor is to be mounted externally, the jumper between B2 and B3 for the internal regenerative
resistor must be removed. Refer to 7.6 Connecting Regenerative Resistors for the selection.
No built-in regenerative resistor is provided to 7.5 kW SERVOPACKs. Be sure to prepare the externally
mounted regenerative resistor.
The following table shows examples of regenerative resistors.
* 1. The values in parentheses are for the optional JUSP-RA05 regenerative resistor.
* 2. The values in parentheses are for the optional JUSP-RA18 regenerative resistor.
The external regenerative resistor must be purchased by customers. Refer to the table below for selecting an
external regenerative resistor. Refer to 7.6 Connecting Regenerative Resistors for the connection.
Applicable SERVOPACK Specifications for a Regenerative
Resistor Mounted in a
SERVOPACK
Min. Allowable
Resistance
(Ω)
Resistance (Ω) Capacity (W)
Single-phase 200 V
SGDH-A5AE
−−40
SGDH-01AE
SGDH-02AE
SGDH-04AE
Three-phase 200 V
SGDH-05AE
50 60 40
SGDH-08AE
SGDH-10AE
SGDH-15AE
30 70 20
SGDH-20AE
25 140 12
SGDH-30AE
12.5 140 12
SGDH-50AE
8 280 8
SGDH-75AE
(3.13)
∗1
(1760)
∗1
2.9
Three-phase 400 V
SGDH-05DE
108 70 73
SGDH-10DE
SGDH-15DE
SGDH-20DE
45 140 44
SGDH-30DE
SGDH-50DE
32 180 28
SGDH-75DE
(18)
∗2
(880)
∗2
14.2