6.8 Peripheral Devices
6-25
6
(2) Three-phase, 200/400 V
Select one of the following noise filters according to SERVOPACK capacity. For more details, refer to 2.6.3
Noise Filters and DC Reactors.
Refer to 7.2.3 Typical Main Circuit Wiring Examples for the connection method.
(a) FN Series
Model FN258L-7/07 FN258L-16/07 FN258L-30/07
Dimensional Drawings
External
Dimensions
in mm (in)
Symbol Dimensions
A
255 ± 1 (10.04 ± 0.039) 305 ± 1 (12.01 ± 0.039) 335 ± 1 (13.19 ± 0.039)
B
126 ± 0.8 (4.96 ± 0.031) 142 ± 0.8 (5.59 ± 0.031) 150 ± 1 (5.91 ± 0.039)
C
50 ± 0.6 (1.97 ± 0.024) 55 ± 0.6 (2.17 ± 0.024) 60 ± 0.6 (2.36 ± 0.024)
D
225 ± 0.8 (8.86 ± 0.031) 275 ± 0.8 (10.83 ± 0.031) 305 ± 1 (12.01 ± 0.039)
E
240 ± 0.5 (9.45 ± 0.020) 290 ± 0.5 (11.42 ± 0.020) 320 ± 0.5 (12.60 ± 0.020)
F
25 ± 0.3 (0.98 ± 0.012) 30 ± 0.3 (1.18 ± 0.012) 35 ± 0.3 (1.38 ± 0.012)
G
6.5 ± 0.2 (0.26 ± 0.0079)
H
300 ± 10 (11.81 ± 0.39) 400 ± 10 (15.75 ± 0.39)
J
1 ± 0.1 (0.039 ± 0.0039)
L
9 ± 1 (0.35 ± 0.039)
O
M5
P
AWG16 AWG14 AWG10
Specifications
480 VAC, 7 A 480 VAC, 16 A 480 VAC, 30 A
Applicable
SERVOPACK
SGDH-
Three-
phase
200 V
05AE
08AE
10AE
15AE
20AE
30AE
Three-
phase
400 V
05DE
10DE
15DE
20DE
30DE
−
Manufacturer
Schaffner Electronic
Side view
Front and side views
G
P
B
O
E
A
DH
L
C
F
J
Kommentare zu diesen Handbüchern