Seitenansicht 42
FSP Amplifier Short Form Installation Guide Inspection and Maintenance
43
7.3.2. Replacing the Battery
1. With the FSP Amp lifier's control power turned ON, rep lace the old
battery with a new one.
2. Turn OFF the FSP Amp lifier's control power to clear the absolute
encoder battery alarm (A.83).
3. Turn ON the FSP Amplifier's control power.
4. M ake sure that FSP Amp lifier is op erating normally after p ower is
turned on.
Battery replacement is now completed. After rep lacing the battery ,
initialize the absolute encoder. Refer to the Sigma FSP Servo Sy stem
User's M anual (Document # YEA-SIA-FSP-3), Initializing of Absolute
Encoder.