For GPD515 Adjustable Frequency Drives
Change 0 4/18/97 Page 1 of 6 Doc. No. 02Y00025-0422
Change 1 9/19/00
Traverse Control
FLASH Memory Software Option
Part Number: GPD515C-XXXX-CS006
(1)
With this factory-installed FLASH software, the
GPD515 has the ability to modulate the output
frequency around the set frequency reference.
This function provides an evenly wound roll for
those winding applications that would
experience localized build-ups without this
feature. The terms disturb, p-jump, ribbon
break and wobbulator are also used to
describe this function.
Specifications:
P-Jump Function / Inertia Compensation
P-Jump ON/OFF Select
P-Jump Limit
Adjustable Duty Cycle
Sawtooth Waveform Generation / Ribbon
Break
Percent Trim Adjustment
Independent P-Jump Adjustment
Independent Accel/Decel Times
Control Mode: P-Jump in V/f only
Serial Communications: DeviceNet,
Profibus, Modbus Plus, Modbus RTU.
This document is an addendum to Technical
Manual TM4515, listing the effect of this soft-
ware on the parameters in the drive and
function descriptions in the manual.
(1) XXXX refers to the base Model Number of
the drive in which the software is installed.
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - Traverse Control

For GPD515 Adjustable Frequency Drives Change 0 4/18/97 Page 1 of 6 Doc. No.

Seite 2 - Change 1 9/19/00

Change 0 4/18/97 Page 2 of 6 Doc. No. 02Y00025-0422Change 1 9/19/00 1.0 Wiring Wire the incoming power, motor, and accessories and

Seite 3 - Traverse Param

Change 0 4/18/97 Page 3 of 6 Doc. No. 02Y00025-0422Change 1 9/19/00 3.0 Startup Procedure 1. Perform the start-up procedure using

Seite 4 - Enabled

Change 0 4/18/97 Page 4 of 6 Doc. No. 02Y00025-0422Change 1 9/19/00 4.3 New Program Parameters The Traverse (Disturb) function giv

Seite 5 - Disturb WF Amp

Change 0 4/18/97 Page 5 of 6 Doc. No. 02Y00025-0422Change 1 9/19/00 Disturb WF Amp P1-02= 0.0 % P1-02 Disturb Waveform Amplit

Seite 6 - P1-05= 0.0 Sec

Change 0 4/18/97 Page 6 of 6 Doc. No. 02Y00025-0422Change 1 9/19/00 Neg Slope Time P1-04= 0.0 Sec P1-04 Negative Slope Time S